• Facebook
  • Linkedin
  • Youtube
  • Twitter
packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Barrier And Permeation Properties Test Equipment

/

Water Vapor Permeability Analyzer

/Gravimetric Method Water Vapor Permeability Analyzer -W303 2.0

Gravimetric Method Water Vapor Permeability Analyzer -W303 2.0

Product introduction

The W303 WVTR tester is designed and produced based on the test principle of weight method (weight reduction) and as per the standards of GB/T 1037 and ASTM E96, etc. It is suitable to measure the water permeability performance of film, sheets, papers, packagings and other related materials in the industries of food, pharmaceutical, medical equipment, daily chemicals, Photovoltaic electronics, etc, providing wide range and high efficiency water vapor transmittance detection for high, medium and low water vapor barrier materials.


Inquiry now
Product Detail

Test principle

Adding distilled water to a dry, clean test dish, put the test dish sealed by pre-processed sampl into the test chamber, by controlling temperature and humidity, make the distilled water in the test dish evaporate, the evaporated water vapor is absorbed by the drying device through the film, by measuring decreasing weight change of distilled water in the test dish over time, obtain the parameters of water vapor permeability of the sample, etc.  



Standards

ASTM E96/E96M, ASTM D1653, TAPPI T464 ISO 2528, DIN 53122-1, JIS Z0208



Technical Parameters

Item

Technical parameters

Test range

0.1~10000 g/(m2·24h)

Test precision

0.0001 g/(m2·24h)

Temperature control range

15~55℃

Temperature control accuracy

±0.1

Humidity control range

10%RH dry method

Humidity control accuracy

±2%RH

Test area

50.24 cm2

Sample size

Φ90 mm

Sample thickness

3mm

Number of test sample

3 pieces

Power

1300 W

Power supply

AC 220 V50 Hz 


 


Product Features

 High precision load cell

The instrument is equipped with high-precision weighing sensor, which is with high weighing efficiency, stable performance,  resolution up to 0.0001 g/(m2·24h).

Temperature control The semiconductor stabilizer automatically controls the temperature, and the temperature control accuracy is 0.1

 Meeting the test requirements of high throughput, wide range and high applicability

The instrument is equipped with 3 chambers with independent data, which can meet the requirements of high throughput testing and testing efficiency is high. 

Wide measuring range 0.1~10000 g/(m2·24h) meets the testing demand of high, medium and low barrier materials. By using customized fixtures also can measure the water vapor transmission of bottles, bags, bowls and other packaging parts. 

 Outstanding shape, easy operation, real time visual curve

The product is designed from the Angle of ergonomics and technical aestheticsExquisite 3D printed shell, smooth lines, beautiful fashion, novel and unique  

Automatic operation, one key test, automatic judgment, automatic shutdown.

Real-time display four groups of curves of transmittance - time, temperature - time, humidity - time, weight - time, curves support preview hiding function.



Application field

 

Films

Water vapor transmittance test of various plastic films (PP / PET / PE / PVC / BOPP / CPP, etc.), plastic composite films, paper plastic composite films, metal composite films, co-extrusion films, aluminum films, degradable packaging films (PLA / PBAT / PBS, etc.)

 

Sheet

Water vapor transmission rate test of solid pharmaceutical hard sheet (PP/PVC/PTP, etc.), metal composite sheet, rubber sheet and other sheet materials

 

Paper, cardboard and their composites

Water vapor transmission rate test of paper and cardboard such as coated paper, silicone paper, aluminum paper for cigarette packs, paper-aluminum-plastic composite sheet, etc.

 

Medicinal patch

Water vapor transmission performance test of medical plasters

 

Package

Customized fixtures can be extended to packaging parts, such as the water vapor transmission rate of medical polyethylene bottles, sealed bags, medical ointment tubes, infusion hoses, plastic trays, etc.

 


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Moisture vapor transmission rate GBPI Advanced WVTR Infrared Method Moisture Vapor Transmission Rate ASTM F1249 - W401 2.0
W401 2.0 water vapor transmission rate tester is designed and manufactured according to GB/T 26253 and ASTM F1249 standards, based on the testing principle of infrared method, it provides wide range and high efficiency water vapor transmission rate test for high, medium and low barrier materials is suitable for water vapor transmission performance testing of films, sheets, paper, packaging and other related materials in the fields of food, medicine, medical equipment, daily chemistry, photovoltaic electronics, etc. It is an ideal configuration instrument for off-line or on-line testing of the barrier properties of packaging materials for production units in the packaging industr
Moisture vapor transmission rate WVTR MVTR Water Vapor Permeability Analyzer Cup Method W301
One test chamber water vapor permeability analyzer using weight reduction method is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Professional Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate supplier Packaging lab equipment high accuracy barrier film water vapor permeability analyzer moisture vapour transmission rate
Application W413 2.0 water vapor permeability tester is designed to test the water vapor transmission rate (WVTR) of films or sheets materials.
Gravimetric Method Water Vapor Permeability Analyzer Intelligent Gravimetric Method WVTR Tester W301 2.0
Application W301 2.0 water vapor permeability analyzer is designed to test the water vapor transmission rate (WVTR) of films or sheets materials with the principle of Gravimetric Method.
Gravimetric Method Water Vapor Permeability Analyzer Infrared Method Water Vapor Permeability Analyzer W401L
Infrared method water vapor transmission rate tester W401L is a high-end precision packaging material testing instrument, newly developed and upgraded by GBPI Research and Development Team based on ASTM, GB standard requirements and market demand. It is used to test the water vapor transmission rate of samples under set temperature and humidity conditions. It is suitable for the water vapor transmission rate performance test of films, sheets, papers, packages and various materials in the fields of food, medicine, medical equipment, daily chemistry, photovoltaic electronics, etc.
Professional high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0 supplier high accuracy barrier film Electrolytic sensor method water vapor permeability analyzer-W203 2.0
Introduction Based on the test principle of electrolytic sensor method, W203 2.0 Water Vapor Permeability Analyzer is designed and manufactured according to GB/T 21529, ISO15106-3 standard, based on the test principle of electrolytic method. W203 2.0 is suitable for the water vapor transmission performance test of films, sheets, papers, packages and various materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It is an ideal configuration instrument for testing the barrier properties of packaging materials in the packaging production industry whether offline or online
WVTR Testing Equipment W812 Water Vapor Permeability Analyzer(Cup Method) WVTR Testing Equipment For Packaging
Product introduction This product is based on the test principle of cup method water vapor transmission, and is designed and manufactured according to ASTM E96, GB/T 1037 standards, and provides a wide range and high efficiency water vapor transmission rate detection for low, medium and high water vapor barrier materials. test. It is suitable for the water vapor transmission performance test of films, sheets, paper, fabrics, non-woven fabrics and related materials in the fields of food, medicine, medical equipment, daily chemicals, etc.
Professional Water Vapor Permeability Analyzer--AUTO W809 supplier Water Vapor Permeability Analyzer--AUTO W809
Water Vapor Permeability Analyzer -AUTO W809 is designed and manufactured in accordance with ASTM E96, GB/T 1037 standards, and provides a wide range of high-efficiency water vapor transmission rate testing for low, medium and high water vapor barrier materials with the  principle of Gravimetric Method.
WVTR Testing Equipment Moisture vapor transmission rate (MVTR)-AUTO W806
product description This product is based on the principle of water vapor transmission test by cup method and designed and manufactured with reference to ASTM E96, standard, providing a wide range and high efficiency water vapor transmission rate test for low, medium and high water vapor barrier materials. It is suitable for water vapor transmission performance testing of films, sheets, papers, fabrics, nonwovens and related materials in the fields of food, pharmaceuticals, medical devices, daily chemicals, etc.
water vapor transmission rate WVTR MVTR Water Vapor Permeability Analyzer-W405 L
Infrared method water vapor transmission rate tester W405L is a high-end precision packaging material testing instrument, newly developed and upgraded by GBPI Research and Development Team based on ASTM, GB standard requirements and market demand. It is used to test the water vapor transmission rate of samples under set temperature and humidity conditions. It is suitable for the water vapor transmission rate performance test of films, sheets, papers, packages and various materials in the fields of food, medicine, medical equipment, daily chemistry, photovoltaic electronics, etc.
WVTR Testing Equipment Gravimetric Method Water Vapor Permeability Analyzer-AUTO W812
product description This product is based on the test principle of cup method water vapor transmission, and is designed and manufactured according to ASTM E96, GB/T 1037 standards, and provides a wide range and high efficiency water vapor transmission rate detection for low, medium and high water vapor barrier materials. test.
Falling Dart Impact Tester Falling Dart Impact Tester GBD-L2
GBD-L2 falling dart impact tester is suitable for testing materials such as plastic film or sheet and steel plate coating with a thickness of less than 1mm. Under a given height of free falling dart impact, it can measure the energy (in Quality to express results) of plastic films,thin section specimens and other materials. Through the impact resistance test, it can prevent the packaging surface from being damaged when the packaging material is impacted or dropped due to insufficient toughness of the packaging material, and effectively avoid the product from being damaged due to impact or falling in the circulation link. It can be used in scientific research, teaching, industrial and mining enterprises, laboratories, research institutes and quality supervision departments.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2024 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact