Melt Flow Tester

/GBB-R1 Melt Flow Indexer (MFI)

GBB-R1 Melt Flow Indexer (MFI)

Introduction

It is used to determine the MFR & MVR value of the melt flow rate through the standard die every 10 minutes when various plastics and gums pass through a certain temperature and load in a viscous flow state. It is suitable for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments. 

  • Brand:

    GBPI
  • Item NO.:

    GBB-R
  • Payment:

    L/C
  • Product Origin:

    China
  • Shipping Port:

    Guangzhou port
Inquiry now
Product Detail

Test standards

  B-T3682-2018  Determination of melt flow rate and melt volume flow rate for thermoplastics

· ISO1133: 1997  Determination of melt mass flow rate MFR and melt volume flow rate MVR for thermoplastics

· ASTM D1238  Standard test method for determination of flow rate of thermoplastics melt by extruded plastimeters

 

Product advantages

1. The heating cylinder is made up of 304 stainless steel or alloy, for the reason that in high temperature metal material is easily oxidation rust while the melting flow index tester usually performs long-time work at high temperature(up to 400~500 degrees).

2. The melting flow index rate instrument is equipped with dual sensor configuration to get precise temperature control and better temperature gradient so that the instrument can work longer.

3. According to the national standard, function that four minute countdown after feeding is added in the machine.

4. The RS232 interface is available to be connected to the computer to output data(optional).

5. The last test conditions can be directly displayed after boot-strap to avoid users resetting test parameters each time ,reducing the workload of the operators.

6. The maximum temperature can be up to 450~500℃。(optional, special instructions when ordering.

7. After long time test of strong corrosive plastic such as full fluorine plastic, the accuracy of the instrument is non-destructive.

8. Meeting standardsISO 1133, ASTM D1238, GB/T3682

 

Applications

This kind of instrument can be used to test the melt flow rate(MFR) figures of all kinds of plastic and resin in the viscous flow state.  It is not only suitable for the high melting temperature engineering plastics of polycarbonate, polyarylsulfone , fluorine plastic and nylon but also suitable for some other low temperature plastic products which are made up of  polyethylene(PE), polystyrene(PS), polypropylene(PP), ABS resin, polyoxymethylene(POM) and polycarbonate. So it is not only widely used in the plastic production, petroleum and chemical industry but also in the relevant institutions such as scientific research units and the community inspection departments.

The melt flow rate instrument is suitable for measuring the thermoplastic melt mass flow rate following the determination in the standard ”GB/T3682-2000 thermoplastic melt mass and volume flow rate measurement”. The standard is equivalent to the requirement in the ISO 1133:1997 and can meet the ASTM D1238 test.

Considering the beautiful appearance and convenient operation ,the desktop structure of the melt flow rate instrument makes the equipment performance reliably and stably. Besides, the high-precision control instrument using fuzzy PID algorithm for temperature control has the feature of high sampling precision and high speed control.  

 

 

Product advantages

1fast heating speedminimal overshoot             

2high precision of constant temperature

3A constant temperature can be quickly restored after packing .     

4Test parameter calibration and correction is convenient.

5Manual and automatic cutting test methods are optional.       

6The instrument is equipped with LCD working platform.

7The test results are automatically printed putout equipped with a printer.

 

Specifications

Items

Melt flow index

Temperature Range

RT-400℃

Temperature drift

4hour≤0.5℃

Display Device

 Touch screen controlled

Temperature fluctuation

± 0.2℃

Temperature uniformity of 10mm-70mm above the die

± 1℃

Temperature display resolution

0.1℃

Time display resolution

0.1S

Cutting timing range

1-999S adjustable

Mouth mold diameter

Φ2.095±0.005mm ( Mouth Radius : 1.05 mm + 0.005 )

Discharge hole length

8.000 ± 0.025mm

Piston rod diameter

9.474 ± 0.007mm

Piston rod length

6.35 ± 0.13mm

Loading container diameter

Φ9.550 ± 0.007mm

Test range

0.1-150g / 10min

Farmar precision

± 0.5%

Displacement measuring encoder

Omron photoelectric rotary encoder

Testing scope of mass method

0.1-150g /10min

Test range by volumetric method

50-5000cm³/10minIt can measure up to 5000 cm3/10min by using the plugging die

Output way

Micro automatic printout

Blanking way

Hand automatic cutting can be switched

Test farmar ( weights)

 total 8 grades, 8 sets of weights

Power supply

AC220V±10%   50HZ  

 

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
6 GBB-R2 Auto Melt Flow Indexer
Product introduction It is used to determine the MFR&MVR value of the melt flow rate through the standard die every 10 minutes when various plastics and gums pass through a certain temperature and load in a viscous flow state. It is suitble for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments.
7 GBPI hot selling Melt flow Indexer with ISO1133 Stander for Petrochemical industry
GBPI Melt Flow Indexer is a high prcise melt testing instruments for the measurement of thermoplastic melt flow rate(MFR) in quality control and research applications. It is suitable to meassure meltg flow charactor of PP,PE,POM, AR,PC,ABS plastic and plastic productions, widely used in plastic raw materials production, petrochemcial industry, scientific research departments and commodity inspection department.
6 GBPI hot selling plastic raw materials producion high precise melt testing instrument
GBPI Melt Flow Indexer is used to measure thermoplastic melt mass flow rate (MFR) and melt volume flow rate (MVR). It is suitable to meassure meltg flow charactor of PP,PE,POM, AR,PC,ABS plastic and plastic productions, widely used in plastic raw materials production, petrochemcial industry, scientific research departments and commodity inspection department.
COF Testing Flexible Packaging Film Coefficient of Friction Tester COF Testing
The Coefficient of Friction Tester equipment performs tests to most of the recognised international test standards including IS0 8295 and ASTM 1894-78.
Adhesive Tape Roller Pressing Machine Plastic Film Adhesive Tape Rolling Pressing Machine
The Adhesive Tape Roller GX-Y2 is suitable for plastic film and cellophane decorative prints (including composite film prints) produced by gravure printing process. It is also used to test the adhesion state of the surface layer formed by vacuum coating, surface coating, compounding and other related processes.
Xenon arc lamp aging test chamber Xenon arc lamp aging test chamber GB-OXD-15P
  1.Profile Xenon lamp aging test chamber simulates the full spectrum lamp with Xenon arc lamp to reappear the destructive wave. It serves for the environmental simulation and accelerated test for research and development, product development and quality control. Besides, the chamber also applies to the choice of new material, weathering test after composition of material and improvement for the current material. It simulate different environment, and show the material changes under the explosion of sunlight.   The chamber meets the standard: GB/T16585-1996 , GB14522-93 , GB/T16422.3-97, ASTM D2565 and so on. The Chamber is to determine the color fastness, aging resistance of textiles, plastics, coatings, rubber products or other materials by objecting to the simulated conditions of nature weather (sun, rain, temperature and humidity, etc.).     Technical parameters   2.Material of construction u Full spectrum lamp u Optional filter system u Water spraying function u Humidity control u Temp. control system in the chamber u Sample fixed hold of irregular shape u USA imported xenon arc lamp u Easy installation and operation, seldom daily maintainance. u Service life time deepens on the irradiance level, usually 1600hrs. It’s easy to replace the lamp, with filter of long service life time to ensure the necessary spectrum. 3.Technical parameters Model No., equipment name GB-OXD-15P Xenon aging test chamber Interior sizes   W500×D500×H600mm  Exterior sizes W1050×D1050×H1750mm (or so) Temperature range 0℃~80℃ Controller imported programmable 7inch touch screen Machine components material inner and outer 304# stainless steel Sample holder Aluminum alloy frame base Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection. Temp. deflection ±2℃  (without lighting) Humidity range 30%~98%R.H Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H) without lighting Light source imported full spectrum xenon arc lamp(average useful life 1600hrs) Raining time 1~9999min (adjustable) Raining period 1~240min, interval(cut)adjustable lamp power Test period for Temp., irradiation, condensation, spray can be adjustable Lamp 1.8KW Wave length range 290-800nm heating power (or so) 4.0KW humidification (or so) 2.0KW Light irradiance 1200w/m2 Distance between arc center and sample holder: 350~380mm Revolving speed of sample holder ≥1r/min  water spray period a. spray time: 0~99h59min (Continuing or adjustable) b. stop time: 0~99h59min, (Continuing or adjustable)   lighting time Continuing programming control available black panel temp. 85±3℃ cooling method Mechanical wind cooling; Room temp. less than 26℃ is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition. 4.Temperature & humidity running control system controller imported programmable 7inch touch screen precision range set precision: temp. ±0.1℃, humid: ±2%R.H, indicated precision: temp.±0.1℃,humid.: ±1%R.H temp. & humid. sensor Platinum Resistance(PT100Ω/MV) black panel temp. double-metal black panel temp. thermometer water-supplying system auto-control humidication water-supplying, Xenon arc lamp with cycling cooling water circulation system low noise heat-resistance conditioning motor, multi-blade centrifugal wind wheel control system mainly consists of operation panel, central controller, kinds of key-pressing sw., status indicating lamp, excution electric device etc.. 5.Structure section of machine body The chamber consists of several section: chamber body, control system, refrigeration system, heating system, humidation system, wind system, raining system, lighting system and so on. Chamber body a. With integrated structure, the chamber consists of up left part as working room, up right part as electric controller which is convenient to control, down part as compressor cooling group, sample holder rotation device, Xenon lamp condensation water box, water pump and other executive devices. b. Inner wall of chamber adopts international SUS304# material. c. Temp. insulation material is polyurethane foam and ultra-fine fibre glass, with good temp. insulation result, no frost and condensation on the external surface of chamber. d. condensate water outfall set at the bottom of chamber e. Environmental heat-resistance silicon sealing tape as the material of door frame. f. Viewing window with eye-protective film on its surface to protect eyes from being injured by Xenon lamp. external chamber body a. Seal of door adopts the double-layer of refined silicone rubber with reliable sealing effect and no aging or hardening phenomenon under high or low temperature. b. Single door (embedded handle); c. Viewing window, antifrost device and lamp equipped on the door viewing window Size:25 cm W × 30 cm H;equipped with Anti-radiation hollow glass 6.Electric control section of chamber a. As the core part of chamber b. Air pressure switch as the main switch to control the main circuit; c. Safety measures for electric section: it warns and cut electricity automatically after tested the action from following protection devices: a) overheat protection in working room b) lockage of phase, leakage protection c) overcurrent protection of motor d) overpressure/overload protection of cooling machine e) short out/overload protection of heater, humidifer f) fusing protection of fuse 7.Working section of chamber Condensation section of compressor. a.Cooling system: as the core part of cooling system, we adopt one set of compressor of Tecumseh from France in this case to ensure the cooling requirement in the working room. b.For adjustment technology and design of cooling system, we take an efficiency processing way to ensure the adjustment for the cooling amount and consumption of cooling system under the normal running, to make the failure rate down to the economical statue. c.Cooling evaporator: it locates in interlayer at one side of chamber which ventilate by force from blast motor to exchange heat fast. d.Cooling method of cooling system: forced air cooling Cooling refrigerant:Environmental R404a; Heating system a. Heating method: heating directly in the chamber; b. Military level stainless steel heating tube used, with fast and stable heating to keep temperature in the working room from rapid change. It with corrosion resistance, anti-high-low temperature, no leakage and other advantages. c. With SSR (solid relay)output control, without noise, reliable working, long service life time, fast switching, low interference from outside, and easy operation etc.. Rain system.   it consists of nozzle, solenoid valve, water-supplying and connecting pipe. Lighting system. It consists of xenon lamp, lamp cover, lamp contactor and other controlling parts. Energy compensation is got by adjusting samples distance, pressure and current. Wind system  It locates in the interlayer at the back of chamber, there are heater, fan blade, evaporator, PT100 temperature samples sensor etc.. when wind machine running, the air is intaken to the channel from working room, and blow out from the bottom after cooled; the air exchanged in the working room with samples is intaken again to the channel and mix; after several circulation, it will reach the purposed temperature, and ensure the high index of temp. and humid in the chamber at the same time. Cooling dehumidification system take the compressor of world brand Tecumseh from France to keep constant temperature, decrease the humidity in the working room and cool the xenon lamp. Humidification Steam generator: to generate steam from water Water level control: control the water inlet by solenoid valve, and water level by liquid level switch to provide the signal for water-supply and warning. Air circulation section Cycling channel and winding machine inside the chamber, it uses the high efficiency cooling machine and energy adjusting system, efficiency heat exchange to reach the aim of temperature change, which also improves the airflow and heat exchange between airflow, heating and humidification, as a result, it improves the humidity uniformity in the working room. 8. Enclosured files: operation manual, warranty card 9. Machine running requirements Temp. 5℃~+32℃ Humidity ≤85% Power supply AC220(±10%)V/50HZ    10. Core components parts Remark: replacement of some small parts of the same quality is possible because of material shortage.    
gas generator High purity nitrogen hydrogen and air gas generator for gas chromatography
gas generator can generates high purity nitrogen, hydrogen and air; it can supply stable and high quality gas for Gas Chromatography
Film Heat Shrinkage Tester GBK-D1 DIN 53369-1976 Pet Film Heat Shrinkage Tester Thermal Shrinkage Tester For Plastic/PVC /OPS Film
Film Heat Shrinkage Tester tests various heat shrinkage propertiesforthe filmaccording to the principle of air heating (air bath).Suitable for heat shrinkable films which produced with polyethylene, ethylene copolymers and their mixtures, such as beverage labels, bottled bundle packaging, sausage shrinkage packaging, outer film of daily chemical products, outer film of cigarette boxes, etc. It is a device that can accurately and quantitatively measure the thermal shrinkage force, cold shrinkage force, shrinkage rate, shrinkage time and other properties of plastic films during thermal shrinkage.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530 is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Oxygen Gas Permeability Tester Coulometric Sensor Method Oxygen Permeability Analyzer Y310L
Introduction This product is designed and manufactured based on the coulometric sensor method and conforms to GB/T 19789、ASTM D3985.This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier properties with high accuracy and high efficiency.Y310Lis applicable to the determination of oxygen permeability of plastic films, sheeting, paper, and other packaging materials used in food, pharmaceutical, medical apparatus, consumer products, photovoltaic and electronic industries, etc.
Face mask tester Multifunctional Tensile Tester for Face Mask - GBH-3
To test the tensile strength, peeling strength, heat sealing strength, tearing strength, piercing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials
Oxygen Gas Permeability Tester Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the coulometric sensor method testing Oxygen, and is designed and manufactured with reference to ASTM D3985 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy,it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact