Introduction

N530 2.0 is based on the test principle of differential pressure method, It's designed with reference to GB/T 1038, ISO 2556 and other standards. Adopt high-precision pressure sensor and automatic pressure difference keeping technology, high test accuracy. It is suitable for the gas permeability test of films, sheets, papers, packages and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It provides a wide range and high-efficiency gas transmission rate test of high, medium and low gas barrier materials.

  • Brand:

    GBPI
Inquiry now
Product Detail

Test Principle

According to the principle of differential pressure method. Place the processed sample between the upper and lower chambers, use a vacuum pump to evacuate the entire gas circuit system, and then add an experimental gas of an atmospheric pressure to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the pressure gradient, the gas permeates from the upper chamber to the lower chamber through the membrane, then the system can calculate the barrier performance parameters such as the gas permeability of the sample through the pressure change of the lower chamber.

 

 

Standards

ISO 2556, ISO 15105-1, ASTM D1434, JIS K7126-1, YBB 00082003GB/T 1038

 

Specifications

Item

Technical parameter

Test range

0.01~50000 cm3/(m2·24 h·0.1 MPa), It can be expanded the upper limit of the volume to test maximum 600000 cm3/(m2·24h·0.1MPa)

Test accuracy

0.0001 cm3/(m2·24 h·0.1 MPa)

Temperature control range

15~60

Temperature control accuracy

±0.1

Vacuum

10 Pa

Vacuum resolution

0.01 Pa

Test pressure

0.1 MPa

Test gas

O2CO2N2, etc.

Permeation area

50.24 cm2

Sample size

Φ110 mm

Sample thickness

2 mm

Available test quantities

1~3pcs

Equipment dimension

690 mm*620 mm*390 mm

Power

750 W

Voltage

AC 220V50Hz 

 

 

 

 

Features

 Patented core technology for efficient and accurate testing

Patented automatic pressure differential technology, which automatically maintains the pressure difference between the two sides of the sample (the pressure differential can be adjusted freely), good stability and low failure rate due to a built-in high-precision pressure sensor with a resolution of 0.01 Pa.

The semi-conductor refrigeration sheet can control the temperature bidirectionally and automatically, the control accuracy reach to 0.1°C.

Original imported vacuum pump with high vacuum efficiency and low noise, the ultimate pressure can reach 0.1 Pa.

The new pneumatic air circuit control system, Excellent sealing performance that sample can be locked by one-button style automatic fixture.

 High throughput, wide testing range and high applicability

The instrument is equipped with 3 chambers, which supports simultaneous testing of three identical or different samples, independent operation, independent data, and high test efficiency.

The testing minimum reach to 0.01 cm3/(m2·24 h·0.1 MPa), which can meet the test requirements of  high, medium and low barrier materials.

With the optional addition accessories, it can measure the gas transmission rate of bottles, bags, bowls and other packages. At the same time, it supports the permeability test of different gases such as oxygen, carbon dioxide, nitrogen, and air.

 Professional calibration service with accurate and reliable data

 

Our company has the "National Standard Substance Grading Certificate" for gas transmission rate approved and issued by the "General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China", the standard substance number (GBW(E) 130541 / GBW(E) 130542); The national standard material is used to calibrate and test the instrument to ensure the accuracy, versatility and authority of the test data.

 

Application

 

Films

Various plastic films (PP/PET/PE/PVC/BOPP/CPP, etc.), plastic composite films, paper-plastic composite films, metal composite films, co-extruded films, aluminized films, degradable packaging films (PLA/PBAT/PBS etc.) and other membranous materials

 

Sheet

Solid medical hard sheet (PP/PVC/PTP, etc.), metal composite sheet, rubber sheet and other sheet materials

 

Paper and cardboard

Coated paper, carbon paper, silicone paper, aluminized paper, paper-aluminum-plastic composite sheet and other paper, cardboard

 

Medicinal patch, warmer patch

Medical plaster treatment patch, warm patch, dysmenorrhea patch, etc.

 

Hygiene

Sanitary napkins, pads and other hygiene products

 

Package

Wine bottles, Coke bottles, peanut oil drums, Tetra Pak packaging, vacuum packaging bags, three-piece cans, cosmetic packaging, toothpaste tubes, jelly cups, yogurt cups, etc. Plastic, rubber, paper, paper-plastic composite, glass, metal bottles Gas transmission rate test of bags, cans, boxes and drums

 

Gases

Oxygen, carbon dioxide, nitrogen, air, helium, etc.

 

 

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Air Transmission Tester Air Permeability Analyzer for Textile- N900
N900 Air Permeability Analyzer to test the air permeability of many textile, including technical fabric, non-woven and breathable textile products.  
Gas Permeability Analyzer N500 2.0 Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530 is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Gas Permeability Analyzer N530 L Gas Permeability Analyzer
Introduction Based on the test principle of the differential pressure method, N530 is designed with reference to the GB/T 1038 standard and used to test the gas transmission rate (quantity) of film or sheet materials.
Gas Permeation Analysis Gas Permeation Analysis System GTR-10H
Product introduction The GTR-10H gas permeation analysis system consists of a differential pressure permeation device and a gas chromatograph. It can test and analyze the gas permeability of various single-component gases and mixed gases, and can accurately calculate the permeability, permeability coefficient and other parameters of each component gas. The test gas has a wide range of types and high accuracy, and is suitable for gas permeation testing in the fields of fuel cell proton exchange membrane gas permeability testing, hydrogen permeation of hydrogen storage materials, gas density of bipolar plate materials, and natural gas storage materials.   Test principle Place the processed sample between the high-pressure chamber and the low-pressure chamber, and the low-pressure chamber is connected to the gas chromatograph through a quantitative loop. At the set test temperature, use a vacuum pump to evacuate the gas system, and then add a certain pressure of test gas to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the action of the pressure gradient, the gas penetrates from the high-pressure chamber to the low-pressure chamber through the film. The system injects the gas that penetrates into the low-pressure chamber into the gas chromatography column and separates it into various components, and calculates the gas permeability, gas permeability coefficient and other barrier performance parameters of each component.   Standard GB/T 20042.3,GB/T 20042.6-2011,GB/T 1038.1-2022,ISO 15105-1   Specification Item Technical Parameters Test range 2.0×10-12~3.0×10-7 mol/(m2·s.Pa) Detection system Gas chromatography (GC), TCD detector Test gas Gases such as hydrogen, oxygen, nitrogen, carbon dioxide, carbon monoxide, methane, etc., single component or mixed component Gas pressure 0~300kPa Permeation module temperature control range 15~60℃ Temperature control accuracy ±0.1℃ Permeation area 50.24 cm2 Sample size Φ110 mm Sample thickness ≤2 mm Sample quantity 1 piece Power supply AC 220 V,50 Hz   Features Advanced gas chromatography analysis technology The instrument is equipped with an advanced gas chromatography analysis module and a new microcomputer temperature control system, which can achieve 16-step program temperature rise with high temperature control accuracy; it adopts multi-processor parallel working mode, and can be equipped with a variety of high-performance detectors. The instrument is stable and reliable, equipped with a 7-inch color LCD touch screen and a dedicated workstation, which is convenient to operate and easy to process data.   Fully automatic precision control of permeation module test temperature The permeation module uses semiconductor refrigeration chips to automatically control the temperature in both directions, with higher temperature control accuracy, up to 0.1℃.   Can test the permeability of single gas and mixed gas It can measure the permeability of a single gas and the permeability of different mixed gases at the same time, and has a wide range of uses. In addition to its application in the traditional packaging industry, it has broad application prospects in new energy fields such as hydrogen energy.   Intelligent operating system, global certification Self-developed intelligent operating system, modular graphics, flexible setting of test process parameters, and intuitive and convenient operation. Designed according to the GMP Appendix "Computerized System", it has an audit tracking function and multi-level user authority settings, which can meet the needs of the pharmaceutical industry for data traceability. Personalized test reports are set on demand, supporting data output in multiple formats, electronic signatures, and online submission of audit reports.   Laboratory Intelligent IoT Platform The instrument can be connected to the IoT platform to achieve digital network management. Remote authorization to log in to the IoT platform can achieve functions such as managing experimental data, remote diagnosis and troubleshooting. Customers can download the required instrument information, documents, and operation videos on the platform.
Gas permeation testing Gas Permeability Testing Differential Pressure Method N500L
Product Introduction This product is based on the test principle of the differential pressure method, and is designed and manufactured with reference to ASTM D1434, ISO 2556 and other standards. With high-precision pressure sensor and automatic differential pressure maintaining technology, this machine has high test accuracy. It is suitable for the gas permeability test of films, sheets, paper, packaging and related materials in food, medicine, medical equipment, daily chemicals, photovoltaic electronics and other industries. It can be used to test high, medium and low gas barrier materials with outstanding efficiency.
Moisture vapor transmission rate WVTR MVTR Water Vapor Permeability Analyzer Cup Method W301
One test chamber water vapor permeability analyzer using weight reduction method is to test the water vapor transmission rate (WVTR) of films or sheets materials.
Gravimetric Method Water Vapor Permeability Analyzer Intelligent Gravimetric Method WVTR Tester W301 2.0
Application W301 2.0 water vapor permeability analyzer is designed to test the water vapor transmission rate (WVTR) of films or sheets materials with the principle of Gravimetric Method.
Vacuum Decay Leak Detection Tester Dual Pressure Methods Vacuum Decay Leak Detection Tester AUTO GBM-L2
Introduction AUTO GBM-L2 Dual-Pressure Methods Vacuum Decay Leak Detection Tester adopts the test principle of vacuum decay method/pressure decay to detect micro-leakage of finished packaging. It can be applied to packaging systems composed of vials, ampoules, Leakage detection of pre-filled needles, eye drop bottles, HDPE bottles, infusion bottles/bags and other pharmaceutical packaging, food packaging, and chemical industry packaging.   Test principle The host is connected to a sealed test chamber customized according to the sample. When performing the vacuum decay method test, the instrument evacuates the test chamber, and a pressure difference is formed inside and outside the sample. Under the action of the pressure, the gas/liquid in the sample enters the test chamber through the leak hole. The main engine uses the absolute pressure sensor and the differential pressure sensor to monitor the pressure change in the chamber to judge whether the sample leaks. When performing the pressure decay method test, the instrument fills the test chamber with a predetermined air pressure, and the gas in the test chamber enters the sample through the leak hole. The host uses absolute pressure sensors and differential pressure sensors to monitor the pressure changes in the chamber to determine whether the sample is leaking.   Standard ASTM F2338-2009(2013),  YY-T 0681.18-2020,  USP<1207.2>, ASTM F2095   Specification Item Technical Parameters Absolute pressure test range (0~300) kPa Differential pressure test range (-2~2) kPa Detection sensitivity 1~3 μm Balance/Test Time 1~3600 s Vacuum time 1~3600 s Set flow rate 0~3 mL/min Test system Dual Sensor Technology / Dual Cycle Test Test chamber  Customized according to samples Suitable for Vials, ampoules, prefilled needles, infusion bottles/bags, etc. Detection principle Vacuum Decay Method/ Pressure Decay Method Host size 495 mm*455 mm*280 mm Ambient temperature 20℃~30℃ Relative humidity Max 80%,no condensation Working power AC 220V, 50HZ   Features u Dual-Pressure Methods, to help solve testing difficulties The double combination of vacuum decay method and pressure decay method solves the problem of easy misjudgment and false negative for freeze-dried powder injections containing vacuum in the bottle using a single vacuum decay method. Based on dual-sensor and dual-circulation system technology, high-quality absolute pressure sensor and differential pressure sensor, with an accuracy of 0.1% FS, can effectively detect large and small leaks, accurately calculate the leak hole diameter, and give a pass or fail judgment.   The instrument has low sensitivity and good test repeatability For rigid samples, the detection sensitivity is as low as 1 μm, and the test repeatability is as low as 0.8%. The instrument has stable performance, low noise and good repeatability. u Imported brand accessories, excellent performance Imported brand vacuum pump, pumping rate up to 3 L/s, noise as low as 50 DB, high ultimate vacuum, convenient oil level detection and replacement. The imported gas mass flow controller can simulate micro-leaks arbitrarily, with a resolution of 0.001 mL/min, which provides a reliable guarantee for the method verification of instrument sensitivity. u Large size touch screen, intelligent operation Color 7-inch touch screen, clear view, sensitive touch, easy to operate. Equipped with a micro-printer, USB data interface, and supports PC software measurement and control operation. The test software is designed according to the GMP appendix "Computerized System". It has an audit trail function and multi-level authority settings for users, which can meet the needs of the pharmaceutical industry for data traceability. u Personalized customization to meet the needs of different samples For different test samples, it supports customization of suitable test chambers to meet the needs of different tests. For the same type of samples, it supports customized nesting mode, which can realize the sharing of a test chamber for samples of various specifications.   Application       Freeze-dried powder injection Injection Prefill needle       Eye drops Plastic Ampoule BFS Infusion bags   Factory configuration Standard Host machine, vacuum pump, test chamber and 3 sets of yin and yang control (customized as required), 11-inch touch panel, professional software (GMP) Optional Imported gas flow meters, air compressors, printers, calibration certificates  
Professional GF2600-X Spout Sealing Machine for slanted bag supplier GF2600-X Spout Sealing Machine for slanted bag
The spout sealing machine is specialized in automatic casing and heat sealing machines for straws and bags, and can be applied to a variety of different types of straws, straws of different calibers and lengths. Applicable to different bag types, stand-up bag, three-side sealing bag, slanted bag, penguin bag. Products are suitable for a variety of industries, beverages, daily chemicals, medicine, food, etc. It has the characteristics of light weight, small footprint, simple operation and stable performance. The main components are all made of aluminum and stainless steel, which meet the environmental and hygienic quality requirements of food and drug GMP.
Ozone Aging Test Chamber Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)       a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
Oxygen Permeability Analyzer Oxygen Permeability Analyzer - Coulometric Sensor Method
This product is based on the testing principle of the Coulometric Sensor Method testing Oxygen and is designed and manufactured with reference to ASTM D3985, GB/T 19789 and other standards. Adopting high-precision imported oxygen sensor, high test accuracy, it is suitable for oxygen transmission performance testing of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc., and provides a wide range and high-efficiency oxygen transmission rate detection for high, medium and low oxygen barrier materials.
Grating Spectrophotometer Densitometer GBPI Grating Spectrophotometer Densitometer
1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.