• Facebook
  • Linkedin
  • Youtube
  • Twitter
packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Chemical Properties Test Equipment

/

Gas Chromatography

/Gas Chromatograph Test The Quality And Purity Of The Solvent GC9802

Gas Chromatograph Test The Quality And Purity Of The Solvent GC9802

GBPI Gas Chromatograph GC-9802 apply to test the smell and solvent residues of printed packaging materials, test the quality and purity of the solvent.

  • Brand:

    GBPI
  • Item NO.:

    GC9802
  • Payment:

    100% TT In Advance
  • Product Origin:

    Guangzhou China
  • Shipping Port:

    Huangpu
  • Lead Time:

    20-30 day
Inquiry now Download
Product Detail


Solvent Residues Test GC-9802 Gas Chromatograph Application 

GBPI GC-9802 Gas Chromatograph accord with standard QBT 2929, GB/T10004-2008, YBB00132002, mainly use to test the smell and solvent residues of printed packaging materials; test the quality and purity of the solvent. 


Working principle 

Sample of gas, liquid or solid is processed and passes through vaporizing chamber, brought to chromatographic column separation system. Carried by nitrogen, the sample mixture passes and contacts the chromatographic column, and the composition components of the mixture are separated by chromatographic column. Then every separated component is brought to the  Gas Chromatograph detector system, and transformed by the detector to equivalent electronic signal, which is collected and recorded as data, so as to make qualitative and quantitative analysis of the components of the sample mixture. 

 Gas Chromatograph

Technical Parameters


Index of detectors

 

Thermal conductivity detector

Flame ionization detector

Electron capture detector

Flame photometric detector

(TCD)

(FID)

(ECD)

(FPD)

Sensitivity (limit of detection)

≥3000mv.mL/mg

(benzene)

≤1×10-11g/s

(hexadecane)

1×10-13g/ml(γ-666)

5×10-12g/s(P)

5×10-11g/s(S)

Baseline noise

≤10μV

≤1×10-13A

≤40μV

≤40μV

Baseline shift

≤60μv /30min

≤6×10-13A/30min

≤100μv/30min

≤100μv/30min

Linearity range

105

107

104

104

Settling time

≤2h

≤1h

≤2h

≤1h


 GBPI Gas Chromatograph Specifications


1 Microcomputer temperature controller, four-way, digital display.


2 Two kinds of commonly used detectors are optional at the same time.


3 Can control temperature close to room temperature (room temperature +10℃).


4 Column oven with large capacity has auto back opening door. Can perform three-period program heating.


5 Optional configurations: packed column sample injector, capillary column sample injector, gas sample injector and so on.


6 GC-9802 Gas Chromatograph with fault self-diagnosis function, displaying fault location and fault nature at any time.


7 Over temperature protection. When temperature of any way of the four ways exceeds set temperature, the instrument will stop heating automatically.


Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
gas generator High purity nitrogen hydrogen and air gas generator for gas chromatography
gas generator can generates high purity nitrogen, hydrogen and air; it can supply stable and high quality gas for Gas Chromatography
drying oven DHG-9030A Drying Oven
It is used to dry, bake, melt and sterilize test sample, widely used in industrial and mining enterprises, laboratory, research institute, inspection agency, college and so on.
water vapor permeability tester for packaging film Barrier Film Water Vapor Transmission Rate Testing Service
packaging barrier film water vapor transmission rate test also called moisture transmission rate test and WVTR
Mask Tester Respirator Fit Test Machine Mask Tester & Supplies
GB-MH180 Respirator Fit Test Machine is a specialized instrument for measuring leakage ratio of dust concentration quantitatively in and out of mask to select fitted mask and check leakage, which is compatible with the requirements of OSHA and GB 19083-2010 .The Respirator Fit Test Machine is widely used in workplaces such as hospitals, manufacturing plants, production sites, and other testing institutions.
Modified Atmosphere Refrigerator Laboratory Refrigerator to Keep Freshness of Food and Vegetables GQ-300
GQ-300 Modified Atmosphere Refrigerator is a kind of Laboratory Refrigerator with microelectronics technology, is for making preservation experiment on fruits, vegetables, flowers and plants in modified atmosphere conditions, and keeps them fresh by controlling concentration of O2, N2, CO2, and C2H4 and the temperature and humidity in the boxes. It is widely used in industries of microorganisms, environmental, food, research institute and so on.
laboratory product packaging Tensile Strength Measurement Device Polymer Laboratory Equipment Of Plastic Bags
GBH-2 multifunctional single-column electronic tensile tester for plastics, films, fibers, rubber sheets, composite materials, tapes, soft packaging materials, paper, non-woven fabrics, medicine package materials, syringes, bottlescovers, rubber plugs and other packaging materials are tested for mechanical properties to meet the needs of different users.
Spout bag packaging machine Spout Insert and Sealing Machine
GF-2200X Spout Sealing Machine is professionally used for automatic casing and heat sealing of spout and bags. It is suitable for pouch of various diameters, lengths and types. It is the preferred automatic equipment for self-supporting pouches with suction nozzles such as chemical products (laundry liquid, skin care products), and can be customized to connect with the filling production line.
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available. Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
Professional Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M supplier Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M
1 Function Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB / T 11206-2009 Rubber Aging test surface cracking method”, and other relevant standards of the test method. 2.1 Structure  All-in-one machine 2.2 Material a) Inner chamber: SUS304 stainless steel plate b) External chamber: SUS304 stainless steel plate or baking finish. Insulation: rigid polyurethane foam + aluminum insulation cotton with double protection. 2.3 Machine door a) Single door, open from left. b) Window frame / door frame with two silicone rubber seal and anti-condensation heating device. c)With observation window (W220xH250mm), lights above the window and door.  2.4 Requirements for sample holder (for dynamic-type only)   a)At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. c) Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample moving continuously along the same path. d) The time of one revolution of the same specimen is (8 ^ -12) min. The scanning area of the specimen shall be at least 40% of the effective area of the test chamber. Specimen preparation shall conform to the provisions of GB / T 9865.1. The test specimen is preferably cut from the new test piece and, if desired, may be cut from the finished product. At least 3 specimens shall be required for per test condition. The standard length of the specimen is not less than 10mm, and thickness not less than 0.2mm. The length of specimen between the two ends of the clamp before drawing is not less than 40mm. 3 Control panel a) Controller display b) Power switch c) Fault alarm d)Wavelength switch e)light switch button 4 Enclosure configuration a) With a stainless steel SUS # 304 shelf turntable b) One φ50mm lead hole:, and with a hole cover and silicone rubber plug. c) Move casters 4 pcs d) Horizontal mounting brackets 4 pcs e) There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long).
Film Pendulum Impact Tester Pendulum Impact Tester-GBG-L2
Introduction Designed and manufactured according tostandards likeGB/T 8809、ASTM D3420, GBG-L2 Pendulum Impact Tester is suitable for determining pendulum impact resistance of the film materials,composite film,metallic foil and so on. The machine can be used in scientific research, teaching, industrial and mining enterprises, laboratory, research institute and quality supervision department.
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2024 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.

Chat now

Inquiry Now

Home

Products

News

contact