packaging testing equipment Water Vapor Permeation Tester
Products
Home /

Physical Property Test Equipment

/

Optical Tester

/GBPI Grating Spectrophotometer Densitometer

GBPI Grating Spectrophotometer Densitometer

1.Perfect combination of the beautiful appearance and the ergonomic structure design;

2.Combined LED light sources with long life and low power consumption, including UV light;

3.Switchable apertures: Φ2/4/8mm, adapt to more samples;

4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample;

5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.;

6.Two standard observer angles: 2/10, multiple light source modes and color systems;

7.USB mode is widely used.

8.Large-capacity storage space, over 10,000 test data;

9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.

Inquiry now
Product Detail

GBPI launched new model Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard  ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control; especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing; and it’s able to customize single aperture Φ2mm, Φ4mm, Φ8mm.
Under the 45/0 geometric optical illumination and the testing conditions of M0, M1, M2, M3, stipulated by ISO 13655 standard, the instrument can accurately measure the reflectance data of samples. Under multiple color spaces, it can accurately measure various printing density indexes, color difference formulas and color indexes, and can meet the user's regular testing of various parameters.

Product Features

1.Perfect combination of the beautiful appearance and the ergonomic structure design;

2.Combined LED light sources with long life and low power consumption, including UV light;

3.Switchable apertures: Φ2/4/8mm, adapt to more samples;

4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample;

5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.;

6.Two standard observer angles: 2/10, multiple light source modes and color systems;

7.USB mode is widely used.

8.Large-capacity storage space, over 10,000 test data;

9.Especially suitable for process control and quality control of printing plants;

10. PC software has powerful function expansion.

 

 

 

Model

YD5010

Measurement Geometry

45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15

Features

Common spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm.

Light Source

Combined LED Light, UV Light

Spectral separation device

Concave Grating

Detector

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

400~700nm

Wavelength Pitch

10nm

Half Bandwidth

10nm

Measurement Conditions

Compliance with ISO 13655 measurement conditions;
M0 (CIE Light Source A)
M1 (CIE Light Source D50)
M2 (Excluding UV light source)
M3 (M2+Polarized light filter)

Density Standards

ISO Status A, E, I, T

Density index

Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray level

Measurement aperture

Customized one apertureΦ2mm,Φ4mm,Φ8mm optional

Color Spaces

CIE LAB,XYZ,Yxy,LCh

Color Difference Formula

ΔE*ab,ΔE*94,ΔE*00

Other Colorimetric Index

/

Observer Angle

2°/10°

Illuminant

A,C,D50,D55,D65,D75,F2,F7,F11,F12

Measurement Time

About 1.5s

Repeatability

Density: Within 0.01 D

 

Chromaticity value:within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3

Inter-instrument Error

Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) Except M3

Measurement mode

Single Measurement, Average Measurement(2-99)

Size(L*W*H)

184*77*105mm

Weight

About 600g

Power source

Li-ion battery. 5000 measurements within 8 hours

Illuminant Life Span

5 years, more than 3 million times measurements

Display

3.5-inch TFT color LCD, Capacitive Touch Screen

Interface

USB,

Data memory

10000 pcs

Language


Simplified Chinese, English, Traditional Chinese

Working Environment

Temperature: 0~40℃; Humidity: 0~85% (No Condensation);altitude: less than 2000 m

Storage Environment

Temperature: -20~50℃; Humidity: 0~85% (No Condensation)

Standard Accessory

Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate

Optional Accessory

Micro Printer

Send A Message

Leave us a message, we will get back to you ASAP.

Related Products
Professional SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003 supplier SGW-810 Light Transmittance and Haze Tester Haze ASTM D1003
Application Use for test the light transmittance and haze degree of all transparent and semi-transparent parallel plane samples (plastic plate, sheets etc), and turbidity or clarity of liquid samples (water, drinks etc), used in the industries of plastics, membrane, coatings and paints, printing ink, research institute and so on.
Optical Properties Testing P60 Standard Light Source Optical Properties Testing
P60 Standard Light Source Used for color observation, color contrast and color matching in a wide range of industries of printing, paints, printing ink, plastics, dyeing and so on.
ST50 Spectrophotometer GBPI ST50 Spectrophotometer
Spectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory. Application  Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement.   Features  1. Large area photodiode array (dual 20 arrays) sensor  A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility. 1. Adopt D/8 structure and SCI/SCE mode  Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds.  2. Combination of full spectrum LED light source and UV light source The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured. 4. Camera positioning can clearly observe the measured area  The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.
YH1200 haze meter GBPI Spectrophotometer (Core Technology)
  Introduction GBPI haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.   Technical Advantage 1.Double standard ISO&ASTM Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136   2.Easy to operate, faster and more accurate measurement The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.   3.Dynamic measurement Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.   4.With compensation port, so that the measurement data more accurate Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.   5.Easy to measure and widely applicable to samples Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.   6.Quality control software It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.   Application YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.   Specification Product Model GBPI Haze Meter Optical Geometry Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. Integrating Sphere Size Φ154mm Light Source 400nm to 700nm, combined LED light Spectrophotometric Mode / Sensor The PD array detector satisfies CIE V(λ)2 degree visual response Wavelength Range / Wavelength Interval / Semiband Width / Measurement range 0~100% Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Sample Size Thickness <170mm Color Space / Color Difference Formula / Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Observer Angle 2° Illuminant D65,A,C Displayed Data PASS/FAIL Result Measuring Time About1.5s Resolution 0.01unit Repeatability Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) Inter-instrument Error Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Dimension L*W*H=290X211X511mm Weight About7.6kg Power AC 24V, 3A Power adapter power supply Illuminant Life Span 5 years, more than 3 million times measurements Display 7-inch TFT color LCD, Capacitive Touch Screen Data Port USB, Print serial port Data Storage Standard 1000 pcs,sample 20000 pcs Language Simplified Chinese,Traditional Chinese,English Operating Environment 0~40℃(32~104°F) Storage Environment -20~50℃(-4~122°F) Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch Note: The specifications are subject to change without notice.      
Portable Digital Gloss Meter KGZ 1C Intelligent Gloss Tester
  Application used to detect the gloss of plastic film, paper, ink, adhesive, etc. Multi-point measurement and data processing can be performed on the sample, and parameters such as average value, standard deviation and coefficient of variation can be printed directly. The machine has high precision and good stability, and can measure the glossiness of flat products such as paint, paper, plastic, ceramic, stone and metal.   Feature  Full-function intelligent design, light touch key operation.  Automatic measurement and manual measurement function.  For single point or no more than 10 points measurement, calculate the average value, root mean square, coefficient of variation and print out the result.   Standards  Angle International Standard Chines Standard Application 20 ISO-2813 ISO8254 GB9754 GB8807 Coating Plastic 20 TAPPI-T653 ASTM-D1834 GB8941.1 Paper 45 ISO-2767 GB8941.2 Metal compound paper 45 ASTM-C346 ASTM-D2457 GB8807 Ceramics、Plastic 45 JIS-E8741   Coating 60 ISO-2813 ASTM-D2457 GB9754 GB9966 GB8807 Coating Stone Plastic 75 TAPPI-T480 GB9841.3 Paper 85 ISO-2813 GB9754 Coating   Specifications Item Specification Test range 0-199.9 Gloss units Precision ±1.0 Gloss units Stability Not more than 0.5 gloss unit / every 30 minutes Repeatability Not more than 0.5 gloss unit Measuring probe size 180mm×100mm×50mm Power 25w/ 220vAC,50HZ      
Salt Spray Tester Salt spray test chamber GB-OSH-60
  1. FunFunction Salt spray test chamber is used for the quality inspection and corrosion resistance test of a variety of materials, including metal plating, metal, electronic components, chemical coatings, paint, automobiles, motorcycles, metal ware, screws, springs, magnetic materials, organic and inorganic coating, anodizing, anti-rust oil industry etc. after the surface treatment.   1. ecGTechnical parameters   1. MODEL GB-OSH-60 2. Temperature inside chamber 35℃±1℃/ 50℃±1℃ 3. Temperature of pressure barrel 47℃±1℃/ 63℃±1℃  4. Inner size W600 x H400 x D450mm   5. External size W1080 x H1080 x D650mm 6. Temperature Uniformity ≤±2℃ 7. Uniformity Fluctuation ≤±0.5℃ 8. Salt fog settlement 1~2ml/h.80cm2 9. Compressed air pressure 1.00±0.01kgf/cm² 10. Spray mode Continuous or intermittent spray optional 11. Power supply AC  220V   50Hz   1.5KW a)  Temp. range: RT+10℃ ~ 55℃ (temperature up to 50C, thickening PVC or PP material is recommended ) b) Humid. range: ≥93%R.H c) Controller time shown: 9.9s~9990hrs d) Timer: 0~9999hrs. e) Testing method: Neutral salt spray test (NSS test), acetic acid salt spray test (AASS test), salt spray test (SS test), copper accelerated acetic acid salt spray test method for salt spray test (CASS test) and so on; (For CASS test, we recommend the PP material chamber with high temperature resistance) f) Specimen holder: It can meet the tilt test at 15 ℃ ~ 30 ℃ (two layers); g) Air compressor: V-0.013/12.5(Customer provided); discharge pressure:1.25M; flow amount: 0.13m3/min   1. MMMaterial of machine body a) Salt spray chamber adopts the quality PVC reinforced hard plastic plate, the surface is smooth and anti-aging, anti-corrosion; b) Without any FRP material produced on the surface because of discoloration fibrosis. Plastic structure of the chamber is better to meet strong acid salt spray test under long-term without any damage. c) Cover is imported transparent impact-resistant plate which is convenient to test specimen when test, that can cover and the box with a water seal to prevent leakage of salt spray.   2. AccAccording to CSN, JIS, ASTM standards, can be set to constant temperature control: (a) Brine spray test: NSS (neutral); · Temp. inside chamber: 35 ℃ ± 1 ℃ · Pressure air bucket: 47 ℃ ± 1 ℃ (b) Corrosion resistance test: CASS (copper acceleration), AASS (acid) · Temp. inside chamber: 50 ° C ± 1 ° C · Pressure air bucket: 63 ℃ ± 1 ℃   3. Watwatering system. It adopts the auto watering system, supply water when lack of water. 4. HeaHeating system Test temperature inside the cabinets is heated humidification water jacket, the heater adopts advanced titanium protective tube, built-in nickel-chromium alloy infrared heater core. Heating up fast, uniform temperature distribution; and saves about one half of the power compared to FRP tank jacketed heating. 5. ExeExecutive standard GB/T 2423.17 Basic test procedures for electric and electronic products Ka"- salt spray test methods; GB/T 10125 Corrosion tests in artificial atmospheres – salt spray tests; ASTM B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test); JIS Z2371-2000 Methods of salt spray testing etc. ISO 9227 Corrosion tests in artificial atmospheres (Note: 2 collection device is required, bigger models than ZH-SH-90 (270L) is required; In some versions, it specifies over 400liters is necessary)  ASTM B117-18 Standard Practice for Operating Salt Spray (Fog) Apparatus (Note: 2 collection device is required, bigger models than ZH-SH-90 is required )  
tensile strength tester Flexible packaging film tensile properties measurement by tensile tester
To test the tensile strength, peeling strength, heat sealing strength and tearing strength of plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics and other packaging materials, widely used in industries of membrane, packaging, pharmaceuticals, food, inspection agency, research institute, college and so on.
WVTR Testing Equipment Gravimetric Method Water Vapor Permeability Analyzer-AUTO W812
product description This product is based on the test principle of cup method water vapor transmission, and is designed and manufactured according to ASTM E96, GB/T 1037 standards, and provides a wide range and high efficiency water vapor transmission rate detection for low, medium and high water vapor barrier materials. test.
Thickness Tester Plastic Film Digital Thickness Tester
Didital thickness tester is used to make thickness measuring or comparative measuring of plastic film, thin sheet, paper and so on.
Box Compression Tester Box Compression Tester for corrugated box and packing box
Box Compression Tester mainly used in various types of corrugated box and packing box. It is the basic instrument for corrugated carton such as small and medium-sized packing box of the compression strength performance test. The various performance parameters and technical indicators is in line with ISO2872 The Package – Complete and Full Transport Package- Compression Test ", ISO2874 The Package – Complete and Full Transport Package-Stacking Test using pressure testing machine "
Vacuum Freeze Dryer Vacuum Freeze Dryer GB-LGJ-200F
Introduction Factory use vacuum freeze dryer is suitable for drying product such as food, drug products, biological products, Chinese medicine and more. It is to dry product at low temperature to preserve, stabilize, store and increase the life of products.. Freeze vacuum drying is a new type of box structure introduced by the vacuum freeze dryer that combines the refrigeration system, vacuum system, heat transfer oil heating system, and moisture removal system. It uses the space for storing materials in the box to dry. Main Technical Parameters   Item GB-LGJ-200F Drying chamber Freeze-drying area 2.25m2 Layers of shelf 5+1 Temperature scope of shelf -50℃-+70℃ (no-load) Shelf temperature error ±1℃ (in balance) Shelf spacing 70mm Size of shelf 500mm*900mm Condenser Min. Temperature of condenser ≤-70℃ (no-load) Water-capture capability >30Kg Liquid material 22L(thickness 10mm) Defrosting Electric defrosting Final Vacuum degree ≤ 5Pa Style of cooling Fan cooling Main functions Manual + Auto Control Mode, Sensor calibration, Intelligent temperature control, Freeze drying termination reminding and other functions are available.               Technical parameters □ Main configuration   Shelf effective area 2.25 m2 □ Specification   Shelf size 500mm × 900mm   Shelf numbers 5+1(Radiation layer) Top shelf as temperature compensating plate   Material number plate 10 pcs   Shelf spacing 70 mm   Shelf temperature range -50℃~+70℃ (no-load)   Min. condenser temp. ≤ -70℃  (no-load)   System final vacuum degree ≤ 5Pa □ Basic configuration    Installation Power 13.5KW     ★ This is installed power, not operating power. □ Shape and other parts   Dimension(mm): About 1200x2100x1700mm, L*W*H   Weight(Kg):  About 1200   Noise ≤ 80dB   Electrical system Ground protection   Design, production, installation standards According to GMP, GB/T522 6.1-1996   Whole machine test Test, verify data, methods, and equipment support □ Drying chamber components   Shape Rectangular   Roughness of inner wall Ra ≤ 0.6μm   Opening direction Clockwise or anticlockwise (overlooking ,user confirm)   Chamber material AISI 304  stainless steel ◆  Door  material ACRYLIC   Working temperature ≥ 70℃   Thermal insulation material Polyurethane foam □ Shelf components ◆ Shelf material AISI 304  Top and bottom plate thickness 5mm ◆ Shelf structure AISI 304 stainless steel (Patent No. :ZL201020237059.X)   Roughness of shelf Ra ≤ 0.6 μm   Flatness ≤ ±0.5mm / m   Effective shelf size 500mm×900 mm   Amount of shelf 5+1     Effective area of shelf 2.25m2 ◆ Shelf spacing  70 mm   Temperature decreasing rate +20℃ down to -40℃/ within 60 min, (no-load, entrance of silicon oil )   Temperature elevating rate -40℃ up to +20℃/ within 60 min, (no-load, entrance of silicon oil ) ◆ Shelf lowest temperature ≤ -50℃      (no-load, entrance of silicon oil )   Shelf highest temperature ≥ +70℃    (no-load, entrance of silicon oil )   Shelf temperature error ≤ ±1℃ ≤ ±1℃ ( in balance ) □ Condenser components   Condenser Shape Vertical type, cylindrical Compact structure, better water capture ,easy to clean and defrosting ◆ Condenser material AISI 304   Condenser water capture ≥ 30Kg   Condenser temp. Decreasing +20℃--40℃, within 30 minutes ◆   Condenser Min. temp. ≤ -70℃   Defrosting Electrochemical cream ◆ Thermal insulation material Polyurethane foam □ Refrigeration system   Refrigerator France original imported TECUMSEH full closure compressor ◆ Refrigerant Environmentally friendly refrigerant   Refrigerator number 2 sets   Shelf refrigeration 1 sets (shelf refrigeration at same time, indirect refrigeration)   Condenser refrigeration 1 set (shelf refrigeration at same time, direct refrigeration) ★ World famous devices are used to make sure correct, stable, safe and reliable.   High pressure protection device When system’s air discharge pressure exceeds allowed pressure, machine automatically stops working, to avoid an accident.   expansion valve DANFOSS(Denmark)   Top cover valve Castel(Italy)   solenoid valve DANFOSS(Denmark)   Oil separator ZOER   High pressure controller DANFOSS(Denmark)   Disacidify filter DANFOSS(Denmark)   Pressure meter LR/REFCO LR/REFCO(Germany/Swiss) oil submerge  pressure meter   Water cooling condenser Well-known brand □ Vacuum system ◆ Double stage rotary vane pump Tan's Vacuum Pump   Quantity 1 set ◆ Vacuum gauge Reborn   Chamber pumping rate Atmosphere→10 Pa ≤30 minutes(in dry condition)   System Maximum vacuum ≤ 5Pa   System leaking rate ≤ 10 Pa·l / sec □ Liquid circulation system ◆   Liquid low viscosity silicon oil ( 25℃, 5cst ) National qualified product   Liquid tubing material AISI 304, welding, heat  keeping ◆ Circulation pump ★GRUNDFOS, original imports, web rotor canned pump From Denmark brand, world famous brand   Circulation pump quantity 1 set   Heating rate 4kW   Heating control style Solid-state relay ◆ Stainless steel plate heat exchanger Well-known brands   Temperature sensor PT-100 platinum resistance □  Control system ◆ Control style Automatic and manual control ◆ Control system FD-PILOT   Control board SH-HPSC-II   Touch screen MCGS   Intermediate relay CHINT   AC contactor CHINT   Air circuit-breaker CHINT   Wiring terminals: Well-known brands □ Safety protection   Whole machine protection All safety conditions are ready for whole machine, machine can start running.   Operation protection Electrical system have logic interlock, control and protection function   Vacuum pressure Available   Heating system Available   Power cut and supply With safety protection measure   Products protection during sublimation process Heat cutting if vacuum lack   Condenser protection when vacuum pump start Interlock □ Whole machine design   Power 3Ph+N+PE, 380V   Installed power 13.5 KW (this is installed power, not running power)   Whole machine structure Integrated structure (easy for transport and placement)   Whole machine size About  1200x2100x1700mm, L*W*H   Whole machine weight (kg) About 1200   Time of warranty: One year after site acceptance.  
  • Facebook
  • Linkedin
  • Youtube
  • Twitter

Copyright @ 2025 Guangzhou Biaoji Packaging Equipment Co.,Ltd. All Rights Reserved.