- GBPI Spectrophotometer (Core Technology)Introduction GBPI haze meter can easily achieve ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1200 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability. Technical Advantage 1.Double standard ISO&ASTM Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 2.Easy to operate, faster and more accurate measurement The YH1200 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system. 3.Dynamic measurement Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data. 4.With compensation port, so that the measurement data more accurate Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results. 5.Easy to measure and widely applicable to samples Open measuring area, vertical and horizontal testing, suitable for more samples to be tested. 6.Quality control software It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management. Application YH1200 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects. Specification Product Model GBPI Haze Meter Optical Geometry Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Characteristic The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. Integrating Sphere Size Φ154mm Light Source 400nm to 700nm, combined LED light Spectrophotometric Mode / Sensor The PD array detector satisfies CIE V(λ)2 degree visual response Wavelength Range / Wavelength Interval / Semiband Width / Measurement range 0~100% Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Sample Size Thickness <170mm Color Space / Color Difference Formula / Other Colorimetric Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Observer Angle 2° Illuminant D65,A,C Displayed Data PASS/FAIL Result Measuring Time About1.5s Resolution 0.01unit Repeatability Φ20mm,within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) Inter-instrument Error Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Dimension L*W*H=290X211X511mm Weight About7.6kg Power AC 24V, 3A Power adapter power supply Illuminant Life Span 5 years, more than 3 million times measurements Display 7-inch TFT color LCD, Capacitive Touch Screen Data Port USB, Print serial port Data Storage Standard 1000 pcs,sample 20000 pcs Language Simplified Chinese,Traditional Chinese,English Operating Environment 0~40℃(32~104°F) Storage Environment -20~50℃(-4~122°F) Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch Note: The specifications are subject to change without notice.View More
- GBPI ST50 SpectrophotometerSpectrophotometer ST50 is a spectrophotometer developed by GBPI series core technology, using built-in photodiode array (double 20 groups) sensors, imported whiteboard, while taking into account the measurement speed and convenience of operation. The repeatability delta E* AB of ST50 spectrophotometer is easily controlled within 0.03, and the Inter-instrument error delta E* AB is controlled within 0.2, to make the measurement more accurate. And the test data can be used for accurate color analysis and transmission in the laboratory. Application Spectrophotometer ST50 is equipped with one customized measuring aperture, accurate color measurement and stable performance. It is used for accurate color measurement and quality control in plastic electronics, paint ink, textile and garment printing and dyeing, printing, ceramics and other industries, and can be used for fluorescent sample measurement. Features 1. Large area photodiode array (dual 20 arrays) sensor A larger area of double 20 array sensor, strong light saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, independent core technology, and international standards of the same platform, to achieve complete compatibility. 1. Adopt D/8 structure and SCI/SCE mode Spectrophotometer ST50 uses a widely international use D/8 optical structure, SCI/SCE (Specular Component Included/Specular Component Excluded) synthesis technology, support SCI+SCE at the same time fast measurement, test time about 1.5 seconds. 2. Combination of full spectrum LED light source and UV light source The use of 400-700nm full spectrum LED light source ensures sufficient spectral distribution in the visible light range, avoiding the spectral loss of specific bands, strong light will not be saturated, weak light is more sensitive, and fluorescence samples can be easily measured. 4. Camera positioning can clearly observe the measured area The ST50 spectrophotometer has built-in camera. Through the real-time scene-taking of the camera, it can accurately determine whether the measured part of the object is the target center, which improves the measurement efficiency and accuracy.View More
- GBPI Grating Spectrophotometer Densitometer1.Perfect combination of the beautiful appearance and the ergonomic structure design; 2.Combined LED light sources with long life and low power consumption, including UV light; 3.Switchable apertures: Φ2/4/8mm, adapt to more samples; 4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample; 5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.; 6.Two standard observer angles: 2/10, multiple light source modes and color systems; 7.USB mode is widely used. 8.Large-capacity storage space, over 10,000 test data; 9.Especially suitable for process control and quality control of printing plants;10. PC software has powerful function expansion.
- Grating Spectrodensitometer
- Grating Spectrophotometer Densitometer
- Portable Grating Spectrophotometer Densitometer
Tags :
- Fully Automatic Overall Migration Tester-ZF900Full-Automatic Overall Migration Tester AUTO ZF900 has an integrated system design of water bath evaporation, heating and drying, drying and cooling, and constant temperature weighing. It is suitable for testing the total migration (non-volatile matter, evaporation residue) and other items in the fields of purified water, pharmaceutical packaging materials, food packaging, cigarette tipping paper and chemical reagents. It can also be applied to the water content, loss on drying and other items of solid samples, and the total dissolved solids content test in water quality testing.
- overall migration test for plastic
- migration test in packaging
- migration testing in food packaging
- Migration & Non-volatile-matter Content Tester
Tags :
- Tensile Strength Measurement Device Polymer Laboratory Equipment Of Plastic BagsGBH-2 multifunctional single-column electronic tensile tester for plastics, films, fibers, rubber sheets, composite materials, tapes, soft packaging materials, paper, non-woven fabrics, medicine package materials, syringes, bottlescovers, rubber plugs and other packaging materials are tested for mechanical properties to meet the needs of different users.
- standard test method for tensile properties of plastics
- Polymer Laboratory Equipment Of Plastic Bags
- tensile strength measuring instrument
- tensile test for plastic material
- tensile testing machine price
- universal testing machine tensile test
Tags :
- GNP-1 Aluminum foil bursting strength testerApplication GNP-1 Bursting Strength Tester can measure the bursting strength of single-layer or multi-layer paper, and can be used to test the blasting strength of cloth, leather, paper board, thin metal sheet, etc. Use mark transmission pressure, automatically retain the maximum bursting strength value when bursting, decomposition degree is 100 times higher than the needle type.
- ISO 2759
- ASTM D2210
- TAPPI T403
- Aluminum Foil Testing Machine
- ASTM F1140
- bursting strength tester pdf bursting strength tester wikipedia bursting strength tester diaphragm digital bursting strength tester bursting strength of paper bursting strength test standard
Tags :